Bostwick consistency describes how far a prepared sample flows under its own weight during a stated test period. With the same method and conditions, a shorter distance indicates less flow. Before comparing tomato paste offers, check the sample preparation, concentration, temperature and timing. A Bostwick number without those conditions is an incomplete comparison.
Read the unit before comparing the number
On TOMEX product pages, Bostwick is expressed in cm/30 s: centimetres of flow during thirty seconds. Keep that unit beside the result when forwarding a specification to another supplier or laboratory. Do not shorten a purchasing requirement to a bare number; the next person needs to know what was measured.
The Gardco instrument description identifies a flow-distance test for a material moving under its own weight. Treat the result as a method-specific consistency measurement, rather than converting it directly into a rotational-viscosity unit. If your specification instead uses a viscosity instrument, ask your quality team which method the supplier must follow.
Preparation is part of the specification
Two reports can use the same heading while describing differently prepared samples. The USDA tomato-products method includes a defined preparation and reporting procedure. Its existence is a reason to request the procedure, not a reason to assume that every supplier uses that exact method.
Ask whether the sample was diluted, what concentration was tested and how that concentration was determined. Also ask for the test temperature and any conditioning steps. Record the answers with the result so your laboratory can assess whether another report is comparable. Do not infer the test concentration from the Brix of the paste as supplied.
The details to request with a reading
| Detail | What to clarify before comparing |
|---|---|
| Sample identity | Which lot and which product the reading describes |
| Preparation | Dilution or other preparation, including the test concentration |
| Conditions | Temperature and conditioning procedure |
| Timing and unit | Test duration and the distance unit reported |
| Method | Named procedure, instrument and reporting convention |
| Decision | Agreed range and the action if results need clarification |
Use this table as a request checklist, not as a laboratory operating procedure. Your quality team should approve the method and acceptance criteria for the intended product. The supplier and buyer should keep the same version of that agreement with the order.
Keep handling and repeat testing consistent
The CSC Scientific operating instructions explain that instrument setup and temperature control matter during a flow test. Follow the instructions for the actual instrument and the selected product method. A different reservoir, reading convention or preparation step should be clarified before results are treated as interchangeable.
For a purchasing team, the useful next step is documentation: keep the supplier report, the sample identifier and your own test record together. If readings differ, first compare the written conditions and sample history with your laboratory. Do not immediately reject a supplier or accept a batch from an unexplained difference between two numbers.
Compare the grade and the application together
TOMEX lists Hot Break tomato paste and cold-break grades with their published specifications. Those pages help you shortlist a grade, but do not establish that two products at different supplied Brix were tested on an identical basis. Request the relevant method before using the ranges as a laboratory comparison.
Keep the application in the discussion. A purchasing brief can state the intended sauce, the process constraints and the consistency your development team wants to evaluate. That is more useful than asking for the lowest possible reading without describing the finished product. Evaluate the sample in your own formulation before settling the purchase specification.
Separate the specification from the batch result
A specification states what is agreed for the product. A batch Certificate of Analysis records reported results for an identified lot. Ask for both, and compare the same parameter and method. A general product sheet does not tell you which result was obtained for a particular consignment.
When preparing a repeat order, retain the accepted sample reference and the specification version. If a supplier proposes a different grade, ask your quality team whether it needs a new evaluation. Do not assume that a matching Brix or a similar product name makes the change equivalent.
Next step
Send your target consistency and test method to the export team, then request a sample. Review the aseptic drum format and read the hot break versus cold break guide alongside the product specification.
Figures and sources checked on 23 October 2026.
Frequently asked questions
What does a Bostwick result measure?
It reports the distance a prepared sample flows during a stated period under the selected test conditions.
Does a lower reading mean a thicker product?
Under the same method and conditions, a lower reading indicates less flow. Check the conditions before comparing products.
Can I compare pastes at different supplied Brix?
Do not assume the reported readings are comparable. Ask for the test concentration, preparation and temperature for both samples.
Can Bostwick be converted directly to cP?
Do not apply a direct conversion. Ask your laboratory to select and interpret the appropriate measurement method.
What should accompany the reading?
Request the sample or lot identity, method, preparation, temperature, duration, unit and agreed specification range.
Should I test a sample in my recipe?
Yes. Use the agreed laboratory method and evaluate the sample in your intended formulation before approving the grade.